Recall archive
128 recalls · page 2 of 6
Reported Jul 19, 2023
VITROS Chemistry Products Calibrator Kit 20-in vitro diagnostic use only. VITROS Chemistry Products Calibrator Kit 20-…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics
Matched: Brand · Product · Product details — Potential to cause biased results in the upper end of the reportable range for the quantitative measurement of Transferrin, C3, C4, IgA, IgG and IgM.…
FDA (openFDA device enforcement)
Reported Jun 7, 2023
VITROS Chemistry Products Calibrator Kit 11 VANC Reagent Generation (GEN) 50 with affected Assay Data Disk (ADD) for…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Product details — Unavailable to calibrate VITROS Chemistry Products VANC Reagent, Generation (GEN) 50, results in delay of testing
FDA (openFDA device enforcement)
Reported May 31, 2023
VITROS Chemistry Products HbA1c Reagent Kit- IVD for the quantitative determination of percent glycated hemoglobin A1c…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — Potential for both unexpected positive and negative HbA1c results, may result in misdiagnosis
FDA (openFDA device enforcement)
Reported May 10, 2023
VITROS XT 7600 Integrated System - For use in the in vitro quantitative, semi-quantitative, and qualitative measurement…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Product details — MicroTip Pack Opener Assembly Potentially Not Removing or Replacing MicroTip Pack Caps on VITROS¿ 5600 and XT 7600 Integrated Systems, results may be…
2 more products in this recall
FDA (openFDA device enforcement)
Reported Apr 26, 2023
VITROS Immunodiagnostic Products Anti-SARSCoV- 2 Total N Antibody Calibrators programmed onto the Assay Data Disks…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — Incorrect Number of Calibrator Levels (2) Set for the VITROS Immunodiagnostics Products Anti-SARS-CoV-2 Total N Antibody Calibrators in Assay Data…
FDA (openFDA device enforcement)
Reported Jan 11, 2023
VITROS Immunodiagnostic Products Intact PTH Reagent Pack- IVD For the quantitative measurement of intact parathyroid…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — Lower than expected iPTH patient and Quality Control (QC) results, reported negatively biased iPTH results- an average -12% shift in patient sample…
FDA (openFDA device enforcement)
Reported Nov 16, 2022
VITROS Chemistry Products Calibrator Kit 9 -(GEN) 22 of VITROS PHYT Slides For in vitro diagnostic use only. Product…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Product · Product details — Calibration disk Data Release Version (DRV) 6194 to 6200 contain inappropriate calibration mathematics for VITROS Calibration Kit 9 for calibrating…
FDA (openFDA device enforcement)
Reported Sep 14, 2022
VITROS XT 3400 Chemistry System with Version 3.7.2 and below Product Code: 6844458
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — Performing a system shutdown on VITROS XT 3400 and VITROS XT 7600 Systems may cause a positive or negative shift in the electrical current supplied…
1 more product in this recall
FDA (openFDA device enforcement)
Reported Jul 20, 2022
Anti-SARS-CoV-2 IgG Quantitative Reagent Pack- Intended for use on VITROS¿ ECi/ECiQ/3600 Immunodiagnostic Systems and…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — On-Analyzer Stability (OAS) time, supported for 6 weeks; not 8 weeks as is currently stated in the Instructions For Use (IFU).
FDA (openFDA device enforcement)
Reported May 25, 2022
VITROS Immunodiagnostic Products FSH Reagent Pack- IVD 1931922
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — Falsely high or delayed patient and QC results may occur due to low end imprecision. VITROS Immunodiagnostic Products FSH, LH and Prol Reagents Low…
2 more products in this recall
FDA (openFDA device enforcement)
Reported Mar 16, 2022
VITROS Chemistry Products VersaTips, Catalog No. 6801715 A VersaTip sales unit is composed of 1000 tips per box.
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Reason for recall — The lot has a shape deformity which may lead to a 16% reduction in the volume of the sample or reagent dispensed. In cases where the error is not…
FDA (openFDA device enforcement)
Reported Jan 26, 2022
VITROS Immunodiagnostic Products High Sample Diluent A Reagent Pack
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — Lower than expected results for VITROS¿ Immunodiagnostic Products TSH Reagent Pack when diluted with VITROS¿ Immunodiagnostic Products High Sample…
FDA (openFDA device enforcement)
Reported Nov 24, 2021
VITROS Immunodiagnostic Products Anti-HBc IgM Controls, Product Code 6801427 For use in monitoring the performance of…
Low riskThis product is unlikely to cause harm, but it breaks a safety or labelling rule.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Reason for recall — Ortho Clinical Diagnostics confirmed a complaint that some VITROS Immunodiagnostic Products Anti-HBc IgM Controls Lot 1690 Controls Values booklet…
FDA (openFDA device enforcement)
Reported Jun 2, 2021
VITROS CoV2 Ag calibrator (Product Code 6199950) - Product Usage: is a chemiluminescent immunoassay intended for the…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Reason for recall — Ortho investigated and confirmed the potential for unexpected failed calibration, and condition codes associated with the calibration, when using…
FDA (openFDA device enforcement)
Reported May 5, 2021
VITROS¿ Black Reference Slides CATALOG #: J02316 - Product Usage: The Black Reference Slide is a part/ tool used in the…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Reason for recall — Delayed results. Ortho confirmed that two lots of VITROS Black Reference Slides are incorrectly labelled as White Reference Slides. If the customer…
FDA (openFDA device enforcement)
Reported Mar 31, 2021
VITROS Chemistry Products Calibrator Kit 4-(Calibrator values for TIBC only). Used to calibrate VITROS 250/350/5,1…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — Potential total iron-binding capacity (TIBC) results. The VITROS TIBC performance shift will start with the newest Generation (GEN) of VITROS Fe…
FDA (openFDA device enforcement)
Reported Mar 24, 2021
VITROS Immunodiagnostic Products SARS-CoV-2 Antigen Reagent- In Vitro Diagnostic. The VITROS Immunodiagnostic Products…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Product · Product details — VITROS Immunodiagnostic Products SARS-CoV-2 Antigen False Reactive Results Associated When Using Remel M4RT Viral Transport Media
1 more product in this recall
FDA (openFDA device enforcement)
Reported Mar 3, 2021
VITROS Chemistry Products VersaTips - Product Usage: used to dispense samples to MicroSlide assays and sample and…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand — A deformity affecting a specific lot of VITROS¿ Chemistry Products VersaTips. Deformed VersaTips results may be biased by up to +/-16% for both…
FDA (openFDA device enforcement)
Reported Jan 13, 2021
enGen Laboratory Automation System, enGen Track System, Catalog Number ENGEN - Product Usage: intended for use in the…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics, Inc.
Matched: Brand · Product details — A software anomaly may cause an aliquoted sample to be labelled as the incorrect sample. This may lead to results being associated with the wrong…
1 more product in this recall
FDA (openFDA device enforcement)
Reported Sep 2, 2020
VITROS Chemistry Products TBIL Slides- 5 PACK/300 SLDS In vitro Diagnostic quantitatively measure total bilirubin…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics
Matched: Brand · Product · Product details — Etrombopag Interference for VITROS Chemistry Products: TBIL Slides, VITROS BuBc Slides and VITROS XT TBIL-ALKP Slides
2 more products in this recall
FDA (openFDA device enforcement)
Reported Jun 24, 2020
VITROS Chemistry Product AMYL Slides Reagent, AMYLASE/5 PACK/300 SLDS, Product Code 1202670, UDI # 10758750008513 -…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics
Matched: Brand · Product details — Multiple coatings of VITROS Chemistry Products AMYL Slides are showing imprecision on control fluids when compared to the expected within lab SD as…
3 more products in this recall
FDA (openFDA device enforcement)
Reported May 20, 2020
VITROS Chemistry Products CKMB Slides, Creatine Kinase MB, Product Code 805 8232-300 slides, UDI Number 10758750004294…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics
Matched: Brand — The Spanish and Swedish language versions of the IFU state that the assay can be tested with Plasma which is false and could result in biased results.
1 more product in this recall
FDA (openFDA device enforcement)
Reported Nov 13, 2019
VITROS chemistry Products Cl- Slides, Catalog No. 6844471 (which supports Urine CL-). MicroSlides which contain…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics
Matched: Brand — Users may experience intermittent slide dispense issues with some cartridges due to the anti-backup platen failing to advance inside the cartridge.
2 more products in this recall
FDA (openFDA device enforcement)
Reported Aug 14, 2019
VITROS Chemistry Products GLU Slides-Product Code:1707801. IVD VITROS Chemistry Products GLU Slides quantitatively…
Moderate riskThis product could cause temporary or reversible health problems — stop using it.Ortho-Clinical Diagnostics
Matched: Brand — Potentially Biased Results using VITROS Chemistry Products GLU Slides
FDA (openFDA device enforcement)