Reported Dec 25, 2024 · Ongoing

Philips Smart-Hopping 2.0 AP 1.4 GHz. Model Number: 867216

Philips North America LLC

Moderate riskThis product could cause temporary or reversible health problems — stop using it.

What you should do

Stop using the affected lot and contact the recalling firm for the return or refund process. Check the FDA enforcement report for lot-level detail.

Firm contact: Philips North America Llc · 222 Jacobs St · Cambridge, MA · 02141-2289

Is this the product you have?

  • Philips Smart-Hopping 2.0 AP 1.4 GHz
  • Model Number867216
Lot codes and dates
  • GTIN00884838099876
  • Model Number867216. All software versions are affected
  • UDI Numbers

    141 of 141 codes

    • (01)00884838099876(21)DK34706344
    • (01)00884838099876(21)DK33603995
    • (01)00884838099876(21)DK34706512
    • (01)00884838099876(21)DK33402245
    • (01)00884838099876(21)DK34706012
    • (01)00884838099876(21)DK33402324
    • (01)00884838099876(21)DK33603538
    • (01)00884838099876(21)DK34405346
    • (01)00884838099876(21)DK32801033
    • (01)00884838099876(21)DK34705955
    • (01)00884838099876(21)DK40307155
    • (01)00884838099876(21)DK34405363
    • (01)00884838099876(21)DK33604046
    • (01)00884838099876(21)DK34706011
    • (01)00884838099876(21)DK34706010
    • (01)00884838099876(21)DK33402486
    • (01)00884838099876(21)DK34405820
    • (01)00884838099876(21)DK34405539
    • (01)00884838099876(21)DK34405788
    • (01)00884838099876(21)DK33403107
    • (01)00884838099876(21)DK33603456
    • (01)00884838099876(21)DK34706099
    • (01)00884838099876(21)DK32801250
    • (01)00884838099876(21)DK32801095
    • (01)00884838099876(21)DK33604249
    • (01)00884838099876(21)DK33403062
    • (01)00884838099876(21)DK34706432
    • (01)00884838099876(21)DK33403214
    • (01)00884838099876(21)DK33402554
    • (01)00884838099876(21)DK40307129
    • (01)00884838099876(21)DK33603678
    • (01)00884838099876(21)DK32801039
    • (01)00884838099876(21)DK33402660
    • (01)00884838099876(21)DK34706048
    • (01)00884838099876(21)DK33904683
    • (01)00884838099876(21)DK33402439
    • (01)00884838099876(21)DK34405702
    • (01)00884838099876(21)DK40306709
    • (01)00884838099876(21)DK32800996
    • (01)00884838099876(21)DK34405910
    • (01)00884838099876(21)DK32800867
    • (01)00884838099876(21)DK33603918
    • (01)00884838099876(21)DK33604048
    • (01)00884838099876(21)DK33904818
    • (01)00884838099876(21)DK34706539
    • (01)00884838099876(21)DK34405884
    • (01)00884838099876(21)DK33403219
    • (01)00884838099876(21)DK33603727
    • (01)00884838099876(21)DK34706371
    • (01)00884838099876(21)DK33402675
    • (01)00884838099876(21)DK33402648
    • (01)00884838099876(21)DK33604588
    • (01)00884838099876(21)DK33604264
    • (01)00884838099876(21)DK33402127
    • (01)00884838099876(21)DK34706378
    • (01)00884838099876(21)DK32801318
    • (01)00884838099876(21)DK33403095
    • (01)00884838099876(21)DK33603562
    • (01)00884838099876(21)DK34706181
    • (01)00884838099876(21)DK33604554
Amount recalled
4,811 units

Where it was sold

  • Nationwide

Why it was recalled

The following four issues are included: 1. Certain Channel Settings may result in an Access Point preventing a connected client device from roaming to another Access Point potentially causing the client device to appear to drop out from the network. 2. if the Access Point experiences a disconnection from the Access Point Controller exceeding 4 minutes, the Access Point may not transition through the desired state to all for clean reconnection of the client radio link. 3. Potential to experience higher than expected data dropouts, device disassociations/reassociations for their wireless clients, and frequent "Loss of AP" alerts. 4. Potential for the Smart-hopping Access Point is affected by a software issue where the Access Point will resent after 82.85 days when the frame counter reaches its limit. This causes the latest synchronization check to fail and potential for loss of patient data.

This product could cause temporary or reversible health problems — stop using it.

Want the full recall guide?

The guide adds the identifying codes laid out for scanning, symptoms to watch for, a timeline, and news coverage of this recall.

Free recall alerts

Get alerted about new Philips North America LLC recalls

One email when a matching recall is published. No account, no cost, unsubscribe in one click.

Where this came from

Source: U.S. Food & Drug Administration (openFDA)

Read the FDA (openFDA device enforcement) notice

Data as of Sep 19, 5:32 PM UTC

RecallNow is not a government agency. Every fact on this page is published by the FDA, USDA or CPSC and links back to their notice.