Reported Feb 11, 2026 · Ongoing

Brand Name: Da Vinci Product Name: da Vinci X, Xi Surgical System, & da Vinci 5 Surgical System Model/Catalog Number:…

Intuitive Surgical, Inc.

Moderate riskThis product could cause temporary or reversible health problems — stop using it.

What you should do

Stop using the affected lot and contact the recalling firm for the return or refund process. Check the FDA enforcement report for lot-level detail.

Firm contact: Intuitive Surgical, Inc. · 1266 Kifer Rd · Sunnyvale, CA · 94086-5304

Is this the product you have?

  • Brand NameDa
  • Vinci Product Nameda Vinci X, Xi Surgical System, & da Vinci 5
  • Surgical System Model/Catalog Number
    • IS4000
    • IS4200
  • IS5000 Software VersionN/A
  • Product DescriptionThe da Vinci Xi, X, and da Vinci 5 surgical systems
  • each consist of three main componentsthe Surgeon Console (SC), the Vision Cart (VC), and the Patient Cart (PC). The PC is the operative component of the system, and its primary function is to support the instrument arms and camera arm. Each system have four Universal Surgical Manipulators (USMs) also known as arms, which allow the surgeon to control up to three instruments and an endoscope simultaneously to perform surgical tasks (e.g. cutting, suturing, tissue approximation) in a variety of procedures. As the surgeon moves the hand controls within the console, the PC moves the robotic instruments within the patient in a corresponding manner. The da Vinci system and its software are designed such that instruments motion precisely tracks the motion inputs from the hand controls during surgery
  • ComponentThe affected part based on this recall, 380647-xx, USM, is a sub component of da Vinci Surgical Instrument
Lot codes and dates
  • Lot CodeUDI: 00886874114216
  • FDA Medical Device Listing NumberD531324 See
  • attachment Affected Product List UDI00886874114216
  • FDA Medical Device Listing NumberD295931 See
  • attachment Affected Product List UDI00886574119747
  • FDA Medical Device Listing NumberD531324 See attachment Affected Product List da Vinci Xi (U.S.) USM
  • Serial Numbers / System Serial Numbers

    264 of 264 codes

    • 402229
    • SK0835
    • 766250
    • SK2180
    • 797416
    • SK3689
    • 674366
    • SK0095
    • 453952
    • SK0135
    • 10200891
    • RSK8057
    • 675618
    • SK3649
    • 634899
    • SK2504
    • 440133
    • SK0682
    • 362922
    • SK6006
    • 405421
    • SK0449
    • 390728
    • SK0389
    • 608999
    • SK2328
    • 395840
    • SK0523
    • 368190
    • SK0837
    • 441220
    • SK0909
    • 596758
    • SK5711
    • 474567
    • SK0075
    • 376348
    • RSK8009
    • 468435
    • SK1448
    • 586220
    • SK5354
    • 417890
    • SK2763
    • 620604
    • SK2121
    • 454704
    • SK1314
    • 601085
    • SK4517
    • 360714
    • SK2497
    • 502409
    • SK0480
    • 450881
    • SK1012
    • 374877
    • SK2478
    • 614195
    • SK1155
    da Vinci Xi (O.U.S.)

    154 of 154 codes

    • 10144327
    • SK0241
    • 885500
    • SK4083
    • 709052
    • SK2651
    • 10002413
    • SK4695
    • 10531698
    • CX0067
    • 441442
    • SK0934
    • 435551
    • SK0907
    • 10241998
    • SK6332
    • 10318042
    • SK6759
    • 10216387
    • SK6341
    • 10217208
    • SK6341
    • 392890
    • SK0256
    • 10216383
    • SK6250
    • 587895
    • SK0950
    • 789071
    • SK0777
    • 450418
    • SK0388
    • 740913
    • SK2996
    • 392885
    • SK0129
    • 464471
    • SK1034
    • 423008
    • SK0658
    • 726556
    • SK5869
    • 443119
    • SK0925
    • 10340582
    • SK6917
    • 10514694
    • SK7706
    • 818737
    • SK3669
    • 819530
    • SK3669
    • 820601
    • SK3669
    • 10060417
    • SK5032
    • 10061285
    • SK5032
    • 10061291
    • SK5032
    da Vinci X (O.U.S.)
    • 364477
    • SL0052
    • 10233342
    • SL1118
    • 392675
    • SL0264
    • 593091
    • SL0178
    • 10168067
    • SL0255
    • 686701
    • SL0598
    • 686724
    • SL0598
    • 689991
    • SL0598
    • 704719
    • SL0598
    da Vinci 5 (U.S.) USM
  • Serial Numbers / System Serial Numbers10651060 SQ0343 da Vinci 5
Amount recalled
219

Where it was sold

Why it was recalled

Due to a software implementation error that allowed instruments arms failing an important diagnostic test to remain in clinical use. This test was supposed to be used to detect Universal Surgical Manipulator insertion axis ball screws that exhibit the symptoms of being bent and misaligned which is a precursor to potential ball screw fatigue failure/fraction

This product could cause temporary or reversible health problems — stop using it.

Want the full recall guide?

The guide adds the identifying codes laid out for scanning, symptoms to watch for, a timeline, and news coverage of this recall.

Free recall alerts

Get alerted about new Intuitive Surgical, Inc. recalls

One email when a matching recall is published. No account, no cost, unsubscribe in one click.

Where this came from

Source: U.S. Food & Drug Administration (openFDA)

Read the FDA (openFDA device enforcement) notice

Data as of Sep 19, 4:54 PM UTC

RecallNow is not a government agency. Every fact on this page is published by the FDA, USDA or CPSC and links back to their notice.