Reported Apr 1, 2026 · Ongoing

CentrosFLO Hemodialysis Catheters, REF: CENFP15K/A, CENFP15K/B, CENFP17K/A, CENFP19K/A, CENFP23K/A, CENFP27K/A,…

Merit Medical Systems, Inc.

High riskUsing this product could cause serious injury, illness or death — stop using it now.

What you should do

Stop using the affected lot and contact the recalling firm for the return or refund process. Check the FDA enforcement report for lot-level detail.

Firm contact: Merit Medical Systems, Inc. · 1600 W Merit Pkwy · South Jordan, UT · 84095-2416

Is this the product you have?

  • CentrosFLO Hemodialysis Catheters
  • REF
    • CENFP15K/A
    • CENFP15K/B
    • CENFP17K/A
    • CENFP19K/A
    • CENFP23K/A
    • CENFP27K/A
    • CENFP31K/A
    • CENFT15K
    • CENFT15K/D
    • CENFT17K
    • CENFT17K/A
    • CENFT17K/D
    • CENFT19K
    • CENFT19K/A
    • CENFT19K/B
    • CENFT19K/D
    • CENFT23K
    • CENFT23K/A
    • CENFT23K/B
    • CENFT23K/D
    • CENFT27K
    • CENFT27K/A
    • CENFT27K/B
    • CENFT27K/D
    • CENFT31K
    • CENFT31K/A
    • CENFT31K/B
    • CENFT31K/D
Lot codes and dates

28 of 28 products

Products covered by this recall
#BarcodesProduct as published
100884450199992REF:UDI-DI/Lot: CENFP15K/A:00884450199992/H3357122
200884450725917CENFP15K/B:00884450725917/H2797565
300884450200001CENFP17K/A:00884450200001/H2643728, H2644554, H2755843, H2777866, H3357123
400884450200018CENFP19K/A:00884450200018/H2415318, H2466455, H2466456, H2608337, H2632772, H2632921, H2643525, H2643729, H2658246, H2658395, H2663614, H2708827, H2777850, H2817064, H2817066, H2834183, H2834184, H2835774, H2875195, H2892153, H2900496, H2900649, H2918430, H2938756, H2982068, H2998532, H3019164, H3028009, H3089474, H3096774, H3101839, H3110067, H3123035, H3131873, H3139507, H3143969, H3152236, H3328470, H3332131, H3332133, H3357124, H3383280, H3398546
500884450200025CENFP23K/A:00884450200025/H2368055, H2460265, H2543292, H2612929, H2622368, H2623456, H2631340, H2640771, H2663612, H2663613, H2719753, H2812164, H2817069,, H2834179, H2834181, H2847016, H2868174, H2880283, H2897527, H2900497, H2900550,, H2907334, H2911460, H2938761, H2978595, H2990699, H3004608, H3019163, H3049760,, H3049761 H3052479 H3071291 H3075039, H3089475, H3092914, H3096777, H3104588,, H3107507, H3120779, H3131874, H3143970, H3145117, H3191613, H3211721 H3316467,, H3328494, H3332218, H3332219, H3332220, H3351695
600884450200056CENFP27K/A:00884450200056/H2286892, H2480924, H2623453, H2643731, H2643732, H2653626, H2663616, H2777861, H2798003, H2833668, H2834185, H2880284, H2900619, H2907339, H2910719, H2911565, H2978601, H2986646, H2998508, H3004606, H3013812, H3019148, H3096779, H3110068, H3131879, H3143988, H3145119, H3156431, H3357125, H3383281
700884450276068CENFT15K:00884450276068/H2845485,H2907340, H2911505, H2978606, H3004602
800884450820766CENFT15K/D:00884450820766/ H3071303, H3075046, H3116838
900884450200063CENFP31K/A:00884450200063/H2623455, H2643737, H2663617, H3052480, H3071293, H3071294, H3110069, H3113265, H3143998, H3196708, H3328496, H3332421
1000884450276082CENFT17K:00884450276082/H2750962, H2755782, H2777600, H3034899, H3059017, H3059018, H3062346
1100884450295526CENFT17K/A:00884450295526/H2911456
1200884450820773CENFT17K/D:00884450820773/H3139508
1300884450276105CENFT19K:00884450276105/H2632775, H2658397, H2709212, H2817067, H2821275, H2835372, H2856854, H2864393S1, H2884659, H2900500, H2907322, H2907349, H2918517, H2933863, H2937909, H2937910, H2978622, H2999167, H3019145, H3034898, H3049764
1400884450295540CENFT19K/A:00884450295540/H2907422
1500884450725993CENFT19K/B:00884450725993/H2801414
1600884450820780CENFT19K/D:00884450820780/H3049766, H3049767, H3071304, H3075050, H3089478, H3126999, H3144001, H3152238, H3156433, H3162590, H3179819, H3196714, H3221338, H3233980, H3239914, H3253651, H3261220, H3283451, H3306069, H3350849, H3357127, H3357128, H3365884, H3372112, H3398547
1700884450276129CENFT23K:00884450276129/H2368107, H2657097, H2709213, H2719652, H2783586, H2812165, H2834187, H2834188, H2864382S1, H2870049, H2892155, H2898665, H2900501, H2907365, H2911451, H2911452, H2934395, H2971862, H2986161, H2986162, H2998549, H3007025, H3019139, H3028000
1800884450295564CENFT23K/A:00884450295564/H2709157, H2817068, H2911454, H2990794, H3013830, H3019136, H3034895
1900884450726006CENFT23K/B:00884450726006/H2801413
2000884450820797CENFT23K/D:00884450820797/H3049771, H3049772, H3071305, H3071306, H3145122, H3152240, H3170518, H3196713, H3201956, H3211729, H3221345, H3233987, H3239915, H3249275, H3275167, H3301761, H3306072, H3323733, H3332225, H3342600
Amount recalled
35,591

This recall covers 5 products

The agency filed one notice per product. You are reading one of them; the other 4 are below.

Where it was sold

Why it was recalled

Stop using this product now

16F dual-valved splittable sheath introducer due to a design defect, may not split as intended, which may result in hemorrhage, foreign bodies, procedure delay, embolization/thrombosis, impaired catheter function, loss of vessel for future vascular access.

Using this product could cause serious injury, illness or death — stop using it now.

Want the full recall guide?

The guide adds the identifying codes laid out for scanning, symptoms to watch for, a timeline, and news coverage of this recall.

Free recall alerts

Get alerted about new Merit Medical Systems, Inc. recalls

One email when a matching recall is published. No account, no cost, unsubscribe in one click.

Where this came from

Source: U.S. Food & Drug Administration (openFDA)

Read the FDA (openFDA device enforcement) notice

Data as of Sep 19, 4:12 PM UTC

RecallNow is not a government agency. Every fact on this page is published by the FDA, USDA or CPSC and links back to their notice.