Reported Apr 29, 2020 · Terminated
Medivators EndoGator REF 100651. Kit for Olympus 140/160/180/190 Series GI Endoscopes for CO2 Connection with Endogator…
Medivators, Inc.
Moderate riskThis product could cause temporary or reversible health problems — stop using it.What you should do
Stop using the affected lot and contact the recalling firm for the return or refund process. Check the FDA enforcement report for lot-level detail.
Firm contact: Medivators, Inc. · 14605 28th Ave N · Plymouth, MN · 55447-4822
Is this the product you have?
- Medivators EndoGator REF 100651. Kit for Olympus 140/160/180/190 Series GI Endoscopes for CO2 Connection with Endogator EGP-100, Olympus OFP, Olympus AFU-100 & Erbe EIP 2 Irrigation Pump Units. Contents 10. Sterile EO. of 100145CO2EXT Endo SmartCap Irrigation Tubing for Olympus 140/160/180/190 Series GI Endoscopes
- with Extended CO2 Input - Product Usageis intended to be used with an air or CO2 source and/or a pump along with a sterile water source to supply air or CO2 and sterile water to an endoscope during endoscopic procedures
- Lot codes and dates
- Lot # / Case UDI#s: 430358 / 2067796406530322060110430358, 429884 / 2067796406530322060110429884, 428806 / 2067796406530322070110428806, 430568 / 2067796406530322060110430568, 431254 / 2067796406530322070110431254, 431455 / 2067796406530322070110431455, 431603 / 2067796406530322070110431603, 431834 / 2067796406530322070110431834, 431985 / 2067796406530322070110431985, 431973 / 2067796406530322070110431973, 432922 / 2067796406530322070110432922, 432108 / 2067796406530322070110432108, 432921 / 2067796406530322070110432921, 433116 / 2067796406530322070110433116, 433115 / 2067796406530322080110433115.
- Amount recalled
- 53,790 units total
This recall covers 7 products
The agency filed one notice per product. You are reading one of them; the other 6 are below.
Where it was sold
- Nationwide
Why it was recalled
Medivators is recalling Endo SmartCap Tubing due to a manufacturing anomaly that may present during procedures as inadequate insufflation, presence of air bubbles inside the endo smartcap tubing, insufficient water to rinse the endoscope lens, or water leaking from the air/water valve.
This product could cause temporary or reversible health problems — stop using it.
Want the full recall guide?
The guide adds the identifying codes laid out for scanning, symptoms to watch for, a timeline, and news coverage of this recall.
Free recall alerts
Get alerted about new Medivators, Inc. recalls
One email when a matching recall is published. No account, no cost, unsubscribe in one click.
We email you about recalls and nothing else. Every send has a one-click unsubscribe, and you can change your preferences any time without an account.