Reported Apr 22, 2026 · Ongoing
Omnipod 5 Pods. Model/Catalog number: PT-001662 ASM 5PK Pod STRL OPS G6G7
Insulet Corporation
High riskUsing this product could cause serious injury, illness or death — stop using it now.What you should do
Stop using the affected lot and contact the recalling firm for the return or refund process. Check the FDA enforcement report for lot-level detail.
Firm contact: Insulet Corporation · 50 & 100 Nagog Park · Acton, MA · 01720-3440
Is this the product you have?
- Omnipod 5 Pods
- Model/Catalog numberPT-001662 ASM 5PK Pod STRL OPS G6G7
- Lot codes and dates
- Model/Catalog numberPT-001662 ASM 5PK Pod STRL OPS G6G7
- UDI-DI10385083000527
- Lot Codes
PH1U02252541PH1U03282511PH1U03282522PH1U03312511PH1U03312521PH1U04012511PH1U04012521PH1U05052511PH1U08162531PH1U08182531PH1U08182541PH1U09242511PH1U09242521PH1U09242531PH1U09252521PH1U09252531PH1U10152541PH1U10162531PH1U10162541PH1U10172531PH1U10172541PH1U10182531PH1U10182541PH1U10202511PH1U10202521PH1U10202531PH1U10202541PH1U10212531PH1U10212541PH1U10222531PH1U10222541PH1U10232531PH1U10232541PH1U10242521PH1U10242531PH1U10242541
- Amount recalled
- 1,240,115 units
Where it was sold
- Nationwide
Why it was recalled
Stop using this product now
Due to a manufacturing defect, certain Omnipod 5 Pods from 49 lots have an internal soft cannula tear that results in insulin leaking into the Pod instead of being delivered to the user regardless of basal or bolus delivery. This defect results from damage to the unexposed portion of the soft cannula during manufacturing, which would result in a compromised fluid path. The primary failure mode is pump under-delivery due to loss of insulin to an internal leak; in some cases, the defect may also lead to pump shutoff and cessation of insulin delivery when leaked insulin contacts Pod circuity in a manner that results in an electrical short. Under-delivery of insulin (both basal and bolus insulin) or cessation of insulin put users at risk of hyperglycemia, and complications from acute and chronic hyperglycemia, including dehydration, blurry vision, nausea, vomiting, altered mental status, diabetic ketoacidosis (DKA), hyperglycemic hyperosmolar syndrome (HHS), or even death. Users may require hospitalization or medical intervention to treat severe adverse health consequences. Not all devices with the defect will issue an alarm or alert the user. If there is sufficient leakage of insulin to cause a short in the circuity, the Pod will issue a Hazard Alarm that stops all insulin delivery and alerts the user to replace their Pod. In addition, if a user s glucose is trending high and is not responding to insulin delivery, the system may reach the maximum amount of insulin microboluses allowed by the system and trigger the Automated Delivery Restriction (ADR) alert that tells users to check their blood glucose and take appropriate actions (i.e., ADR is a response to persistent hyperglycemia and maximum automated delivery constraints rather than a direct detection of the leak). The magnitude of under-delivery is unknown and based on multiple factors, including how much insulin is being delivered, whether an alarm and/or alert triggers, whether and when the user recognizes the device defect, the duration of Pod use, and the size of the tear.
Using this product could cause serious injury, illness or death — stop using it now.
Want the full recall guide?
The guide adds the identifying codes laid out for scanning, symptoms to watch for, a timeline, and news coverage of this recall.
Free recall alerts
Get alerted about new Insulet Corporation recalls
One email when a matching recall is published. No account, no cost, unsubscribe in one click.
We email you about recalls and nothing else. Every send has a one-click unsubscribe, and you can change your preferences any time without an account.