VITEK 2 Gram Negative test kits containing colistin (cs01n)

Biomerieux Inc.

Moderate riskThis product could cause temporary or reversible health problems — stop using it.

What you should do

Stop using the affected lot and contact the recalling firm for the return or refund process. Check the FDA enforcement report for lot-level detail.

Firm contact: Biomerieux Inc · 595 Anglum Rd · Hazelwood, MO · 63042-2320

Is this the product you have?

  • VITEK 2 Gram Negative test kits containing colistin (cs01n)
Lot codes and dates
  • 71 of 71 codes

    • REF # (Description): 418114 (AST-GN94)
    • 22258 (AST-N102)
    • 412605 (AST-N194)
    • 412921 (AST-N199)
    • 412862 (AST-N201)
    • 412863 (AST-N202)
    • 412924 (AST-N205)
    • 412918 (AST-N210)
    • 413061 (AST-N212)
    • 413083 (AST-N222)
    • 413112 (AST-N225)
    • 413171 (AST-N236)
    • 413172 (AST-N237)
    • 413204 (AST-N239)
    • 413205 (AST-N240)
    • 413391 (AST-N242)
    • 413394 (AST-N245)
    • 413397 (AST-N248)
    • 413572 (AST-N249)
    • 413722 (AST-N253)
    • 413724 (AST-N255)
    • 413725 (AST-N256)
    • 413753 (AST-N261)
    • 414164 (AST-N272)
    • 414286 (AST-N276)
    • 414492 (AST-N279)
    • 414531 (AST-N280)
    • 414532 (AST-N281)
    • 414972 (AST-N288)
    • 415063 (AST-N292)
    • 415369 (AST-N293)
    • 415433 (AST-N295)
    • 416005 (AST-N299)
    • 416241 (AST-N300)
    • 416590 (AST-N303)
    • 416913 (AST-N308)
    • 416914 (AST-N309)
    • 417426 (AST-N315)
    • 417952 (AST-N318)
    • 418204 (AST-N320)
    • 418489 (AST-N322)
    • 418513 (AST-N235)
    • 418514 (AST-N326)
    • 418630 (AST-N328)
    • 418631 (AST-N329)
    • 418675 (AST-N331)
    • 418676 (AST-N332)
    • 418985 (AST-N335)
    • 419077 (AST-N338)
    • 419341 (AST-N339)
    • 420063 (AST-N343)
    • 420440 (AST-N344)
    • 420867 (AST-N347)
    • 420856 (AST-N348)
    • 421258 (AST-N352)
    • 421297 (AST-N353)
    • 421350 (AST-N354)
    • 421351 (AST-N355
    • 421451 (AST-N357)
    • 421441 (AST-N358)
Amount recalled
1,520,000 cards

Where it was sold

Why it was recalled

The investigation demonstrated a high rate of very major errors (resistant isolates calling susceptible) with the VITEK¿ 2 AST-GN colistin (cs01n) compared to agar dilution (the reference method used for cs01n development) and compared to broth-microdilution (recommended method by EUCAST/CLSI).

This product could cause temporary or reversible health problems — stop using it.

Want the full recall guide?

The guide adds the identifying codes laid out for scanning, symptoms to watch for, a timeline, and news coverage of this recall.

Free recall alerts

Get alerted about new Biomerieux Inc. recalls

One email when a matching recall is published. No account, no cost, unsubscribe in one click.

Where this came from

Source: U.S. Food & Drug Administration (openFDA)

Read the FDA (openFDA device enforcement) notice

Notice updated Jun 19, 2019 · Data as of Sep 19, 4:47 PM UTC

RecallNow is not a government agency. Every fact on this page is published by the FDA, USDA or CPSC and links back to their notice.