Reported Feb 15, 2023 · Ongoing

GE Nuclear Medicine 600/800 series systems, specifically

Ge Medical Systems Israel, Functional Imaging

High riskUsing this product could cause serious injury, illness or death — stop using it now.

What you should do

Stop using the affected lot and contact the recalling firm for the return or refund process. Check the FDA enforcement report for lot-level detail.

Firm contact: GE MEDICAL SYSTEMS ISRAEL, FUNCTIONAL IMAGING · 4, Hayozma St · Tirat Carmel · N/A

Is this the product you have?

GE Nuclear Medicine 600/800 series systems, specifically

9 of 9 products

Products covered by this recall
#Product as published
1870 CZT O540+ Gantry 7.25mm
2D670 CZT Gantry 7.25mm
3DISCOV NM/CT 870 CZT
4Discovery NMCT 670 CZT O540+
5NM/CT 870 CZT CYBER DEFENCE
6NM/CT 870 CZT O540
7NM/CT 870 CZT WSO
8NM/CT 870 CZT
9NM/CT 870 CZT O540+ 7.25MM; Emission Computed Tomography System
Lot codes and dates
  • a) 870 CZT O540+ Gantry 7.25mm: Catalog number H3906CW , UDI/DI 01008406821408432187CZ6304211200300
  • Serial Numbers
    • 87CZ63042
    • UDI/DI 01008406821408432187CA6305311210100
  • Serial Numbers
    • 87CA63053
    • UDI/DI 01008406821408432187CX6301111181000
  • Serial Numbers
    • 87CX63011
    • UDI/DI 01008406821408432187CY6302011190300
  • Serial Numbers
    • 87CY63020
    • UDI/DI 01008406821408432187CY6303511191100
  • Serial Numbers
    • 87CY63035
    • UDI/DI 01008406821408432187CZ6304011200100
  • Serial Numbers
    • 87CZ63040
    • UDI/DI 01008406821408432187CX6300411180700
  • Serial Numbers
    • 87CX63004
    • UDI/DI 01008406821408432187CX6300911180900
  • Serial Numbers
    • 87CX63009
    • UDI/DI 01008406821408432187CB6307211220700
  • Serial Numbers
    • 87CB63072
    • UDI/DI 01008406821408432187CA6306111211100
  • Serial Numbers
    • 87CA63061
    • UDI/DI 01008406821408432187CY6303211191000
  • Serial Numbers87CY63032; UDI/DI To be provided
  • Serial Numbers
    • 87CB63075
    • 87CA63058
    • 87CB63070
    • 87CB63069
    • 87CB63071
    • 87CB63077
    • 87CA63063
    • 87CB63064
    • 87CB63078
    • 87CA63062
    • 87CB63067
    • 87CA63057
    • 87CA63060
    • 87CB63065
    • 87CB63068
    • 87CB63074
    • UDI/DI Not Applicable
  • Serial Numbers87CY63019, 87CA63054, 87CZ63043, 87CA63055, 87CY63028, 87CY63037, 87CZ63044, 87CZ63045, 87CZ63048, 87CZ63041, 87CY63024, 87CY63017, 87CX63007, 87CX63008, 87CX63006, 87CX63014, 87CY63022, 87CX63015, 87CY63025, 87CX63010, 87CZ63052, 87CY63027, 87CY63026, 87CY63030, 87CZ63046, 87CX63013, 87CY63036, 87CZ63047, 87CY63033, 87CY63016, 87CX63005, 87CZ63039, 87CX63002, 87CX63012, 87CX63001, 87CY63023, 87CY63018; b) D670 CZT Gantry 7.25mm: Catalog number H3906DD, UDI/DI Not Applicable
  • Serial Numbers
    • CZGA55003
    • CZGA55004
    • CZGY55001
    • UDI/DI To be provided
  • Serial Numbers
    • CZGB55006
    • CZGA55005
    • CZGB55007
  • c) DISCOV NM/CT 870 CZT
    • Catalog number H3906CW
    • UDI/DI 01008406821408432187CY6303811191200
  • Serial Numbers87CY63038; d) Discovery NMCT 670 CZT O540+: Catalog number H3906DD , UDI/DI Not Applicable
  • Serial NumbersCZGZ55002
  • e) NM/CT 870 CZT CYBER DEFENCECatalog number H3906FK, UDI/DI To be provided
  • Serial Numbers87DB82001
  • f) NM/CT 870 CZT O540Catalog number H3906CW , UDI/DI Not Applicable
  • Serial Numbers
    • 87CY63021
    • 87CZ63050
    • 87CZ63049
    • 87CZ63051
    • 87CY63034
  • g) NM/CT 870 CZT WSO
    • Catalog number 5376204-70-20
    • UDI/DI 01008406821408432187CA6305911210800
  • Serial Numbers
    • 87CA63059
    • UDI/DI 01008406821408432187CB6307611221000
  • Serial Numbers
    • 87CB63076
    • UDI/DI 01008406821408432187CB6307311220800
  • Serial Numbers
    • 87CB63073
    • : Catalog number H3906CW
    • UDI/DI To be provided
  • Serial Numbers87CB63066; : Catalog number To be provided, UDI/DI To be provided
  • Serial Numbers87CA63056
  • h) NM/CT 870 CZTCatalog number H3906CW, UDI/DI Not Applicable
  • Serial Numbers87CY63031; i) NM/CT 870 CZT O540+ 7.25MM: Catalog number H3906CV, UDI/DI 01008406821408432187CX6300311180700
  • Serial Numbers
    • 87CX63003
    • UDI/DI 01008406821408432187CY6302911190800
  • Serial Numbers87CY63029
Amount recalled
86 units

This recall covers 6 products

The agency filed one notice per product. You are reading one of them; the other 5 are below.

Where it was sold

  • Nationwide
  • PR

Why it was recalled

Stop using this product now

A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury.

Using this product could cause serious injury, illness or death — stop using it now.

Want the full recall guide?

The guide adds the identifying codes laid out for scanning, symptoms to watch for, a timeline, and news coverage of this recall.

Free recall alerts

Get alerted about new Ge Medical Systems Israel, Functional Imaging recalls

One email when a matching recall is published. No account, no cost, unsubscribe in one click.

Where this came from

Source: U.S. Food & Drug Administration (openFDA)

Read the FDA (openFDA device enforcement) notice

Data as of Sep 19, 5:44 PM UTC

RecallNow is not a government agency. Every fact on this page is published by the FDA, USDA or CPSC and links back to their notice.