Reported Oct 8, 2025 · Ongoing

MAGNETOM Lumina (DE). Model Number: 11344916.

Siemens Medical Solutions USA, Inc.

High riskUsing this product could cause serious injury, illness or death — stop using it now.

What you should do

Stop using the affected lot and contact the recalling firm for the return or refund process. Check the FDA enforcement report for lot-level detail.

Firm contact: Siemens Medical Solutions USA, Inc · 40 Liberty Blvd · Malvern, PA · 19355-1418

Is this the product you have?

  • MAGNETOM Lumina (DE)
  • Model Number11344916
Lot codes and dates
  • Model Number11344916
  • UDI Numbers

    130 of 130 codes

    • (01)04056869230740(21)196458
    • (01)04056869230740(21)196591
    • (01)04056869230740(21)196655
    • (01)04056869230740(21)196355
    • (01)04056869230740(21)196733
    • (01)04056869230740(21)196668
    • (01)04056869230740(21)196477
    • (01)04056869230740(21)196343
    • (01)04056869230740(21)196553
    • (01)04056869230740(21)196519
    • (01)04056869230740(21)196366
    • (01)04056869230740(21)196782
    • (01)04056869230740(21)196617
    • (01)04056869230740(21)196684
    • (01)04056869230740(21)196502
    • (01)04056869230740(21)196539
    • (01)04056869230740(21)196280
    • (01)04056869230740(21)196626
    • (01)04056869230740(21)196511
    • (01)04056869230740(21)196643
    • (01)04056869230740(21)196796
    • (01)04056869230740(21)196551
    • (01)04056869230740(21)196495
    • (01)04056869230740(21)196741
    • (01)04056869230740(21)196621
    • (01)04056869230740(21)196611
    • (01)04056869230740(21)196544
    • (01)04056869230740(21)196724
    • (01)04056869230740(21)196776
    • (01)04056869230740(21)196752
    • (01)04056869230740(21)196372
    • (01)04056869230740(21)196350
    • (01)04056869230740(21)196841
    • (01)04056869230740(21)196252
    • (01)04056869230740(21)196508
    • (01)04056869230740(21)196332
    • (01)04056869230740(21)196496
    • (01)04056869230740(21)196753
    • (01)04056869230740(21)196375
    • (01)04056869230740(21)196738
    • (01)04056869230740(21)196260
    • (01)04056869230740(21)196470
    • (01)04056869230740(21)196765
    • (01)04056869230740(21)196334
    • (01)04056869230740(21)196288
    • (01)04056869230740(21)196409
    • (01)04056869230740(21)196737
    • (01)04056869230740(21)196286
    • (01)04056869230740(21)196604
    • (01)04056869230740(21)196446
    • (01)04056869230740(21)196362
    • (01)04056869230740(21)196518
    • (01)04056869230740(21)196619
    • (01)04056869230740(21)196450
    • (01)04056869230740(21)196678
    • (01)04056869230740(21)196349
    • (01)04056869230740(21)196261
    • (01)04056869230740(21)196415
    • (01)04056869230740(21)196386
    • (01)04056869230740(21)196391
  • Serial Numbers

    130 of 130 codes

    • 196458
    • 196591
    • 196655
    • 196355
    • 196733
    • 196668
    • 196477
    • 196343
    • 196553
    • 196519
    • 196366
    • 196782
    • 196617
    • 196684
    • 196502
    • 196539
    • 196280
    • 196626
    • 196511
    • 196643
    • 196796
    • 196551
    • 196495
    • 196741
    • 196621
    • 196611
    • 196544
    • 196724
    • 196776
    • 196752
    • 196372
    • 196350
    • 196841
    • 196252
    • 196508
    • 196332
    • 196496
    • 196753
    • 196375
    • 196738
    • 196260
    • 196470
    • 196765
    • 196334
    • 196288
    • 196409
    • 196737
    • 196286
    • 196604
    • 196446
    • 196362
    • 196518
    • 196619
    • 196450
    • 196678
    • 196349
    • 196261
    • 196415
    • 196386
    • 196391
Amount recalled
130 units

This recall covers 15 products

The agency filed one notice per product. You are reading one of them; the other 14 are below.

2 more are in the archive.

Where it was sold

  • Nationwide
  • GA

Why it was recalled

Stop using this product now

There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.

Using this product could cause serious injury, illness or death — stop using it now.

Want the full recall guide?

The guide adds the identifying codes laid out for scanning, symptoms to watch for, a timeline, and news coverage of this recall.

Free recall alerts

Get alerted about new Siemens Medical Solutions USA, Inc. recalls

One email when a matching recall is published. No account, no cost, unsubscribe in one click.

Where this came from

Source: U.S. Food & Drug Administration (openFDA)

Read the FDA (openFDA device enforcement) notice

Data as of Sep 19, 7:42 PM UTC

RecallNow is not a government agency. Every fact on this page is published by the FDA, USDA or CPSC and links back to their notice.